Skip to product information

E2S: D1xC1X05F / D1xC1X10F

Class I Division 1 explosion-proof combined alarm horn with xenon strobe - 143cd at 5J, 260cd at 10J, 106dB(A), UL464, UL1638

Accreditation
Accreditation image Accreditation image Accreditation image Accreditation image Accreditation image
Coding

D1xC1X05F
NEC Class / Zone
Class I Zone 1 IIC T4 Gb Ta -55°C to +85°C
Class I Zone 1 IIC T4A Gb Ta -55°C to +80°C
Class I Zone 1 IIC T5 Gb Ta -55°C to +60°C (T6: +45°C)

CEC Class / Zone
Class I Zone 1 IIC T5 Gb Ta -55°C to +55°C (T6: +45°C)

NEC Class / Div
Class I Div 1 ABCD T4 Ta -55°C to +85°C
Class I Div 1 ABCD T4A Ta -55°C to +80°C
Class I Div 1 ABCD T5 Ta -55°C to +60°C (T6: +45°C)

CEC Class / Div
Class I Div 1 ABCD T5 Ta -55°C to +55°C (T6: +45°C)


D1xC1X10F
NEC Class / Zone
Class I Zone 1 IIC T3C Gb Ta -55°C to +85°C
Class I Zone 1 IIC T4 Gb Ta -55°C to +70°C (T4A: +55°C)

CEC Class / Zone
Class I Zone 1 IIC T4A Gb Ta -55°C to +55°C

NEC Class / Div
Class I Div 1 ABCD T3C Ta -55°C to +85°C
Class I Div 1 ABCD T4 Ta -55°C to +70°C (T4A: +55°C)  

CEC Class / Div
Class I Div 1 ABCD T4A Ta -55°C to +55°C

Approvals

Videos

More from this collection

E2S: D1xC1X05F / D1xC1X10F

Class I Division 1 explosion-proof combined alarm horn with xenon strobe - 143cd at 5J, 260cd at 10J, 106dB(A), UL464, UL1638

Description

The D1xC1X05F and D1xC1X10F are globally certified alarm horn featuring a re-entrant flare horn combined with a Xenon strobe, available in 5 Joule and 10 Joule versions respectively. The robust Type 4/4X, IP66 marine grade, corrosion-proof aluminum enclosure is approved for Class I & II Div 1, Zone 1 & 20, and IECEx and ATEX Zones 1, 2, 21 & 22 explosion-proof signaling applications.

Featuring 64 alarm tones, each of the available 4 stage/channels can be remotely activated. Class D amplification provides a high sound output at optimum operating current, with a choice of two power modes on select models. The threaded flameproof joint, multiple cable entries, and duplicated, pluggable terminations simplify both installation and routine maintenance. The 24Vdc version is approved for public (alarm horn) and private mode fire alarm use. SIL1 and SIL2 compliant to IEC 61508 (2010) as standard.

Features

D1xC1X05F / D1xC1X10F

  • Maximum sound pressure level output of 106dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronization on multi-beacon & sounder systems
  • User selectable strobe flash rates
  • Field replaceable lens color filter
  • Ratchet adjustable 316 stainless steel bracket
  • Available with custom tone configurations and frequencies
  • Robust corrosion proof aluminum enclosure
  • Duplicate cable terminations
  • UL464 / CAN/ULC-S525 & UL1638 / CAN/ULC-S526
  • Manufacturer warranty: 10 years



Differences

  • Peak Candela - calculated from energy (J): 1,000,000cd (D1xC1X10F), 500,000cd (D1xC1X05F)
  • Effective Intensity - calculated from energy (J): 500cd (D1xC1X10F), 250cd (D1xC1X05F)
  • Peak Candela - measured ref. to I.E.S: 85,544cd* (D1xC1X10F), 46,976cd* (D1xC1X05F)
  • Effective Intensity – measured ref. to I.E.S: 260cd*. (D1xC1X10F), 143cd* (D1xC1X05F)
Approvals
Select product and buy
PART NUMBER: D1XC1X05FDC024CN1A1R/A
Quantity
Sale price  $ 2,636.41 Regular price  $ 3,382.96
Description

The D1xC1X05F and D1xC1X10F are globally certified alarm horn featuring a re-entrant flare horn combined with a Xenon strobe, available in 5 Joule and 10 Joule versions respectively. The robust Type 4/4X, IP66 marine grade, corrosion-proof aluminum enclosure is approved for Class I & II Div 1, Zone 1 & 20, and IECEx and ATEX Zones 1, 2, 21 & 22 explosion-proof signaling applications.

Featuring 64 alarm tones, each of the available 4 stage/channels can be remotely activated. Class D amplification provides a high sound output at optimum operating current, with a choice of two power modes on select models. The threaded flameproof joint, multiple cable entries, and duplicated, pluggable terminations simplify both installation and routine maintenance. The 24Vdc version is approved for public (alarm horn) and private mode fire alarm use. SIL1 and SIL2 compliant to IEC 61508 (2010) as standard.

Features

D1xC1X05F / D1xC1X10F

  • Maximum sound pressure level output of 106dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronization on multi-beacon & sounder systems
  • User selectable strobe flash rates
  • Field replaceable lens color filter
  • Ratchet adjustable 316 stainless steel bracket
  • Available with custom tone configurations and frequencies
  • Robust corrosion proof aluminum enclosure
  • Duplicate cable terminations
  • UL464 / CAN/ULC-S525 & UL1638 / CAN/ULC-S526
  • Manufacturer warranty: 10 years



Differences

  • Peak Candela - calculated from energy (J): 1,000,000cd (D1xC1X10F), 500,000cd (D1xC1X05F)
  • Effective Intensity - calculated from energy (J): 500cd (D1xC1X10F), 250cd (D1xC1X05F)
  • Peak Candela - measured ref. to I.E.S: 85,544cd* (D1xC1X10F), 46,976cd* (D1xC1X05F)
  • Effective Intensity – measured ref. to I.E.S: 260cd*. (D1xC1X10F), 143cd* (D1xC1X05F)

Videos